Polarimeter - ToronAP10™ AutoPlus

Polarimeter - ToronAP10™ AutoPlus integrates advanced automatic photoelectric inspection technology for highly accurate and reliable measurements. It provides seamless operation for determining the optical rotation, density, content, and purity of various substances. Its versatility makes it an indispensable tool across industries such as pharmaceuticals, petroleum, food, chemicals, flavors, spices, sugar production, and academic research.

The ToronAP10 AutoPlus and its advanced counterparts are ideal for quality control and research applications in:

  1. Pharmaceuticals
  2. Food and beverage industries
  3. Chemical analysis
  4. Flavor and fragrance formulation
  5. Sugar production
  6. Academic and industrial research institutes

This robust and versatile instrument offers unparalleled performance for diverse analytical needs.

Polarimeter - ToronAP10 AutoPlus

Polarimeter - ToronAP10 AutoPlus

  • Peltier Temperature Control
    The built-in Peltier system automatically maintains sample temperature within a range of 10 °C to 50 °C, ensuring precise and consistent results.
  • User Calibration System
    Equipped with standard polarization tubes and calibration software, enabling users to easily perform calibration for enhanced accuracy.
  • Large Color Touch Screen
    The device features an intuitive software interface and a high-resolution touch screen for easy operation and data visualization:
    • ToronAP10 Auto: 5.6-inch TFT display.
    • ToronAP10 AutoPlus, ToronAP50 Auto, and ToronAP50 AutoPlus: 8-inch TFT display.
  • Long-Lasting LED Light Source
    High-brightness LED lights with a service life of over 100,000 hours eliminate the need for frequent light source replacements.


Enhanced Features of ToronAP10™ AutoPlus and ToronAP50 AutoPlus

  • Advanced Android System with 8-inch Touch Screen
    The upgraded system simplifies operation and offers a modern user experience.
  • FDA 21 CFR Part 11 Compliance
    Designed to meet strict regulatory requirements, ensuring data integrity and security for pharmaceutical applications.
  • User ID Management
    Allows for user ID creation, deletion, and permission settings to maintain operational control and security.
  • Dynamic Display Functionality
    The timing measurement and atlas display features track and visualize optical rotation changes in real time.
  • Expanded Storage Capacity
    8GB of internal memory for extensive data storage, making it easier to manage and retrieve test results.
  • Enhanced Connectivity Options
    Includes three USB ports for connecting peripherals like U-disks, keyboards, and mice, alongside Wi-Fi capability for printer connections.

ToronAP10 AutoToronAP50™ AutoToronAP10™ AutoPlusToronAP50™ AutoPlus
Measuring range±89.99°Arc; ±259°Z
Measuring ModelOptical Rotation; Specific Rotation; Concentration; Sugar Degree
Min.reading0.001°(optical rotation)
Accuracy

±0.01º(-45º. optical rotation ≤+45º;

±0.02º ( optical rotation<﹣45º or optical rotation>﹢45º)

Repeatability (standard deviation)0.002°(optical rotation)
Min. Transmittance1%
Light SourceLED
Wavelength589.3nm LED
Temperature ControlNoPeltierNoPeltier
Temperature Control Range 10℃~50℃ 10℃~50℃
Temperature Control Accuracy 0.2℃ 0.2℃
Communication PortUSB; RS232USB×3,RS232, Wi-FiUSB×3,RS232, Wi-FiUSB×3,RS232,Wi-Fi
Data Storable10008GB8GB8GB
21CFR Part 11NoNoYesYes
Display5.6 inch8 inch8 inch8 inch
Sample CellUp to 200mmUp to 200mmUp to 200mmUp to 200mm
GraphicNoNo4hours4hours
Power220V AC (±10%) 50Hz (110V is also available)220V AC (±10%) 50Hz (110V is also available)220V AC (±10%) 50Hz (110V is also available)220V AC (±10%) 50Hz (110V is also available)
Calibration SystemOptionOptionOptionOption

Request Quote

Related Articles

Displaying 1 - 3 of 3
Sodium Lamp vs LED: The Better Polarimeter Light

Sodium Lamp vs LED: The Better Polarimeter Light

We're going to make a clear statement here: regarding the light source in your polarimeter, LED technology is a significant step up from the traditional sodium lamp. For years, the scientific community has relied on those familiar yellow sodium lamps.Anyone who's spent time in a lab knows the routine that comes with them: the warm-up delays, the unpredictable lifespan, and the constant need for replacements. We believe there's a more efficient way to work.Key TakeawaysSuperior Performance: LED technology provides instant stability and lasts over 5,000 hours, vastly outperforming the short…
Polarimetry and the International Sugar Scale Explained

Polarimetry and the International Sugar Scale Explained

Global commerce thrives on clear, universal standards. In the sugar industry, that cornerstone of trust and reliability is the International Sugar Scale (°Z). This globally accepted benchmark ensures fairness and consistency in trade, but its power comes from the precise technology used to measure it.To us at Torontech, a solid grasp of the relationship between polarimetry and the international sugar scale is essential for any business focused on accuracy and quality. This guide will walk through the science and how it's applied, connecting the core principles to the equipment that performs…
Manual vs Automatic Polarimeters: Which is Best?

Manual vs Automatic Polarimeters: Which is Best?

Ready to get perfect measurements every single time? We believe every lab deserves results they can trust without the headache. For our partners in the pharmaceutical, food, and chemical sectors, the right polarimeter turns a daily routine into a seamless process. In our view, the choice regarding manual vs automatic polarimeters is about more than just hardware. It is about unlocking better efficiency and total confidence in your data. Here is our perspective on making the right call.Key TakeawaysAutomatic polarimeters are the clear winner for commercial labs as they eliminate the…