Disintegration Tester - ToronDT™ 2SA

Parent Product
Product Categories

ToronDT™ 2SA Disintegration Tester is a high-performance, bathless system designed for precise tablet disintegration testing. It meets USP, IP, and Ph. Eur. standards, featuring fast heating, automated basket lift, individual tablet tracking, and a user-friendly interface with secure login options.   

Accessories

ToronDT Holder for Basket 40 Mesh 24.5 mm (Set of 6) – 0104A00206

ToronDT™  Holder for Basket 40 Mesh 24.5 mm (Set of 6) – 0104A00206

100 ml Vessels (6 rows X 7 vessel each)

100 ml Vessels (6 rows X 7 vessel each)

1000 ml vessels

1000 ml vessels – 1101A00003

 

  • Pharmaceutical Quality Control – Ensures tablets and capsules disintegrate within required timeframes as per USP, IP, and Ph. Eur. standards.

  • Research and Development – Supports formulation studies by evaluating how different excipients and coatings affect disintegration.

  • Production Batch Testing – Validates consistency of disintegration times across multiple batches for compliance.

  • Regulatory Compliance – Generates validation data and printed reports for audit-ready documentation.

  • Training and Education – Provides precise, user-friendly testing suitable for academic and industrial training labs.

  • Specialized Testing – Accommodates different vessel sizes and accessories for varied product testing needs.

  • Meets USP, IP, and Ph. Eur. standards
  • Bathless heating system saves water, time, and energy
  • Maintenance-free design
  • Optimized heater plates ensure fast media heating
  • Automatic basket lift after test completion
  • Tracks disintegration time for each tablet
  • Prints test results and validation data
  • Independent motor and timer with external probe for each basket
  • Magnetically coupled basket for effortless loading
  • Supports up to 50 user logins
  • Secure date & time lock feature
  • Dual test jars
  • Bottom illumination enhances tablet visibility

Model
 
ToronDT™ 2SA
Beaker
 
1000 ml glass beakers (2 nos.)
Basket2 nos. each carrying 6 test positions (dimensions as per latest USP)
Guided disc
 
Perforated cylindrical disc 6 nos. in each basket (dimensions as per latest USP)
 
Printer interface

 
RS232 Serial port
Display
 
20 x 4 LCD
MotorSingle shaft 6V DC motor 10 kg cm torque (2 nos.)
IlluminationGreen LED
Voltage230 V AC, 50 Hz, 550 VA (110V is also available)
No. of strokes
 
30 ±1 strokes/min
Stroke height
 
55 mm ±2 mm
Controlled temperature range
 
15° C to 40° C
 
Temperature resolution
 
±0.5° C
 
Dimension ( L x W x H)360 x 372 x 570
Weight18 kg

Ordering Information

Product Code

Description

Quantity

0241300

ToronDT™ 2SA (Body made of S.S.) -230V
 

1

0221300

ToronDT™ 2SA (Body made of M.S.) -230V
 

1

0231300

ToronDT™ 2SA (Body made of S.S.) -110V
 

1

0211300

ToronDT™ 2SA (Body made of M.S.) -110V

1

Standard Accessories

Part numberDescriptionQuantity

0213A00001

ToronDT™ Beaker 1000 ml2

0201A00009

ToronDT™ PO Six Tube Basket Assembly With Guided Disc (Set of 2)1

0213A00002

ToronDT™ 2SA External Probe2

0201B00053

Keyboard1

Optional Accessories

Part numberDescriptionQuantity

0214A000105

ToronDT™ Heater cover with spacer

1

0214A00004

ToronDT™ Stand for external probe (set of 2)

1

0213A00004

ToronDT™ 2SA Cover - Front & Back (S.S)

1

0213A00002

ToronDT™ 2SA External probe

1

0213A00003

ToronDT™ SA Stroke height lable. (set of 2)

1

0201A00009

ToronDT™ PO Six tube basket assembly with guided disc

2

Request Quote

Back to Main Page

Related Articles

Displaying 1 - 4 of 4
Choosing a Disintegration Tester: Automated vs Manual

Choosing a Disintegration Tester: Automated vs Manual

The disintegration tester your lab chooses is a key indicator of your operational strategy. With increasing demands for speed and flawless compliance, this decision directly impacts workflow, labor costs, and data confidence. The core question in the manual vs automated disintegration testing debate is whether your operation will stick with the traditional hands-on method or benefit from a system that automates the work for you.What is Disintegration Testing?In simple terms, a disintegration tester simulates stomach conditions to measure how long it takes for a tablet or capsule to break…
Your Guide to USP Calibration of a Disintegration Tester

Your Guide to USP Calibration of a Disintegration Tester

The way a lab handles its equipment is what separates the good operations from the great ones. When it comes to the gear that verifies your product's performance, getting the calibration of disintegration test apparatus absolutely correct is a massive factor for success.  Many people see this procedure as a routine task, but from our perspective, a proper disintegration apparatus calibration is a foundational part of product quality. So, we're going to show you how to get this procedure dialed in. This is how you ensure your disintegration testing is indisputably reliable.Why "Good…
Disintegration vs Dissolution vs: A Full Comparison

Disintegration vs Dissolution: A Full Comparison

Let's be direct about what happens after a patient takes a tablet.  A successful therapeutic outcome is a complex process, not a simple one. It depends on a sequence of events, but two of the most critical are disintegration and dissolution.  At Torontech, we see firsthand how getting these steps right is non-negotiable. The success of a formulation hinges on mastering the difference between disintegration and dissolution.Part 1: Disintegration, The Complete Breakdown Think of a new tablet as a solid, compressed unit. Disintegration is the demolition phase. It’s the…
Understanding the Disintegration Test - How Tablets and Capsules Are Evaluated

Understanding the Disintegration Test: How Tablets and Capsules Are Evaluated

Every detail matters in pharmaceutical development. From API selection to tablet coating, each step contributes to the safety, efficacy, and reliability of the final drug product. But there's one process that’s often underestimated in its importance: the disintegration test. If you’re working in pharma, biotech, nutraceuticals, or even dietary supplements, understanding what a disintegration test is, how it works, and why it’s crucial can help you improve product quality, ensure compliance, and avoid costly batch failures. In this article, we’ll walk you through the disintegration…