Bomb Calorimeter ToronBC-3200
Bomb Calorimeter ToronBC-3200 accurately measures the calorific value of solid and liquid fuels like coal, oil, and biomass. With fully automated operation, it delivers results in ≤14 minutes, features precise temperature control (±0.1℃), and ensures reliable data with RS232 connectivity and PT1000 temperature sensing.
Energy & Power Industry - Determination of calorific values for coal, petroleum products, and biomass fuels to optimize energy efficiency in thermal power generation.
Cement & Construction Materials - Analysis of raw mixes and alternative fuels to ensure product consistency and process reliability in cement and building material production.
Chemical & Petrochemical Industry - Precise fuel testing for quality control, safety compliance, and process optimization in chemical and refinery operations.
Research & Academic Institutions - High-accuracy calorimetry for scientific studies, educational programs, and the development of new fuel and material technologies.
Quality Assurance & Certification Labs - Standardized calorific value testing in compliance with ASTM, ISO, and other international standards for certification and regulatory approval.
Environmental & Waste Management - Evaluation of municipal solid waste, alternative fuels, and renewable biomass for energy recovery and sustainable resource management.
- Featuring a large-capacity water tank, the jacket maintains a water temperature variation of under 0.1℃ per test, with heat capacity accuracy within 0.15%.
- It offers automatic temperature regulation, consistent water volume, and total water volume monitoring. The entire testing process is fully automated, ensuring reliable and accurate results.
- Enhanced heat capacity guarantees dependable performance, while the PT1000 platinum resistance enables precise temperature measurement.
- The standard RS232 interface allows seamless connection to a balance and network, with real-time data transmission over the internal network.
| Description | ToronBC-3200 |
| Analysis Time | ≤14min |
| Temperature Resolution | 0.0001K |
| Precision(RSD) (1g Benzoic Acid) | ≤0.15% |
| Heat Capacity Stability | ≤0.25% within three months |
| System Structure | Benchtop/vertical |
| Conformance with Standard | ASTM D5865, ASTM D240, ASTM D4809, ASTM E711, ASTM D5468, ISO 1928, ISO 9831, ISO18125, AS 1038.5, BS EN 15400, BIS1350 |
| Test per Hour | 2~4 |
| Bomb volume | 282ml |
| Calorimeter Type | Isoperibol |
| Oxygen Filling | Semi-automatic |
| Bomb Washing | Manual |
| Max. Bomb pressure | 20Mp |
| Bomb Identity | Yes |
| Gas Requirement | 99.5% Oxygen |
| Water Requirement | Distilled Water |
| Energy Measurement Range | 0~50000J |
| Bucket Filling | Automatic |
| Constant Volumetric Tank with Temp Control Device | Bucket determine water volume automatically |
| Independent Bucket and Jacket Water System | Yes |
| Stirring Method | Blade |
| Power Inverter | No |
| Reproducibility based on analysis of 1g Benzoic Acid | 0.15% |
| Average Temperature Increase | 2℃ |
| Temperature Measurement | PT1000 |
| Working Temperatures | ≤32℃ |
| Cooling method | Refrigerating Device |
| Network | Yes |
| Voltage | AC 220V (-10% +10%)50/60Hz (110V is also available) |
| Max. Power | 0.6KW |
| Dimension | Main body: 500*600*425 Water Tank: 550*356*520 |
| Weight | 65kg |
| Advance Calculation | Yes |
| Analysis Report | Yes |
| Statistics Report | Yes |
| System Monitor | Yes |