48-Well Gradient Real-Time PCR System
48-Well Gradient Real-Time PCR System - ToronPCR™ 480
The ToronPCR™ 480 is a 48-well gradient real-time PCR system built for research labs that need medium throughput and fast assay optimization on one instrument. Independent gradient zones let users test several annealing temperatures or run different thermal profiles in a single plate. Four fluorescence detection channels quantify up to four targets per well, which cuts reagent and sample use. Fiber optic detection carries emitted light directly to photodiodes for clean, consistent signal.
The 480 accepts 8-well strip tubes and single transparent tubes with reaction volumes from 20 to 120 µL. Peltier modules, edge temperature compensation, and precision sensors hold ±0.15°C accuracy and ±0.25°C uniformity. That control reduces well-to-well variation and keeps Ct values steady from edge to center. Detection reaches a single target copy, and the linear dynamic range spans 10 logs.
Labs use this quantitative thermal cycler for gene expression, genotyping, pathogen detection, and transgenic research. Software automates baseline and threshold setting and exports data in several formats. At 47 × 31 cm, the unit fits a standard bench while handling six strips per run. The ToronPCR™ 480 is intended for research use only and is not for diagnostic procedures.
Applications
The ToronPCR™ 480 fills the gap between small benchtop units and full 96-well platforms. Its gradient block and four-channel optics support both routine runs and new assay development.
- Assay Development and Optimization: tests annealing temperatures and thermal profiles side by side to finalize new primer sets quickly
- DNA and RNA Quantification: measures nucleic acid copy number for sequencing prep, cloning, and assay setup
- Gene Expression Analysis: tracks relative expression with reference-gene normalization in cell biology and drug response studies
- Multiplex Gene Expression Profiling: quantifies up to four targets per well to compare pathways in one run
- Pathogen Detection Research: identifies bacterial and viral targets in research samples with probe-based assays
- Genotyping and SNP Analysis: separates alleles with dual-probe assays read in separate channels
- Mutation Screening and Molecular Cloning: flags sequence variants and confirms inserts in transformed clones
- Transgenic Research: detects and quantifies transgene integration in engineered plants and animal models
- Agri-Food Safety and Veterinary Testing: screens food, crop, and animal samples for contaminants and pathogens
Key Features
The ToronPCR™ 480 combines gradient thermal control, four-channel optics, and automated analysis in a mid-size benchtop unit. Each feature shortens assay setup and supports dependable quantification.
- Multi-Zone Gradient Block: runs several annealing temperatures or thermal profiles in one plate to speed up optimization
- Four-Channel Fluorescence Detection: quantifies up to four targets per well, reducing reagent cost and sample volume
- Fiber Optic Detection System: carries light directly to photodiodes for consistent, low-noise signal
- Peltier Heating and Cooling: delivers fast, uniform transitions at up to 4°C/sec heating and 3°C/sec cooling
- Edge Temperature Compensation: offsets perimeter heat loss to cut well-to-well variation
- Precision Temperature Sensors: hold ±0.15°C accuracy and ±0.25°C uniformity for repeatable Ct values
- Single-Copy Sensitivity: detects very low target levels and resolves 1.5-fold differences in singleplex reactions
- Automated Baseline and Threshold Setting: removes manual curve adjustment and speeds up data review
- Dedicated Analysis Modes: cover multiplex expression profiling, pathogen detection, and SNP analysis
- Multi-Format Data Export: moves results into statistics software, LIMS, or reports without retyping
- Cost-Efficient Medium Throughput: processes 48 samples per run without the cost of a full 96-well platform
- Dedicated Technical Support: provides application help and troubleshooting to keep the instrument in service
Theory and Method
Real-time PCR (qPCR) tracks DNA amplification cycle by cycle rather than measuring product only at the end. Each cycle denatures double-stranded DNA near 95°C, anneals primers at a lower temperature, and extends new strands with a thermostable polymerase. A fluorescent reporter, either an intercalating dye such as SYBR Green or a sequence-specific probe, emits light in proportion to the product formed. The instrument records the quantification cycle (Cq or Ct), where fluorescence crosses a set threshold.
Samples with more starting template reach the threshold sooner. Ct falls linearly as the log of the initial copy number rises, so a standard curve converts Ct values into absolute quantities. The ΔΔCt method compares a target with a reference gene for relative quantification. LEDs excite the wells between 475 and 620 nm, and photodiodes read emission from 515 to 670 nm across four filter channels.
Gradient PCR solves a common setup problem: primer pairs bind most efficiently within a narrow annealing window. The 480 drives its Peltier zones to different set points at the same time, so each zone of wells sees a different annealing temperature. Comparing Ct values and melt curves across the gradient shows which temperature gives the strongest, most specific amplification. Edge compensation keeps outer wells on target despite heat loss at the block perimeter.
Technical Specifications
Parameter | Specification |
Model | ToronPCR™ 480 |
Description | 48-well real-time PCR instrument with 4 dye channel filters |
Sample Capacity | 48 wells, 0.2 mL block |
Compatible Consumables | 8-well strip tubes, single tubes (transparent) |
Reaction Volume | 20 to 120 µL |
Excitation Source | LED |
Excitation Range | 475 to 620 nm |
Detection Method | Photodiodes |
Detection Range | 515 to 670 nm |
Detection Channels | 4 |
Temperature Range | 4 to 100°C |
Average Heating / Cooling Rate | 3.0°C/sec / 2.0°C/sec |
Maximum Heating / Cooling Rate | 4.0°C/sec / 3.0°C/sec |
Temperature Uniformity | ±0.25°C |
Temperature Accuracy | ±0.15°C |
Gradient | Independent gradient temperature zones |
Detection Sensitivity | 1 copy |
Fold-Change Resolution | Detects 1.5-fold differences in target quantity (singleplex) |
Linear Dynamic Range | 10 logs |
Dimensions (W × D × H) | 470 × 310 × 280 mm |
Weight | 18 kg |
Intended Use | Research use only, not for diagnostic procedures |