The ToronMVS™ FS full-spectrum microvolume spectrophotometer measures absorbance across 190 nm to 1100 nm using as little as 0.5 µL of sample. Genomics cores, protein labs, and biotech QC teams use it to quantify nucleic acids, proteins, and labeled molecules without dilution. Six path lengths, as short as 0.02 mm, extend the dsDNA range up to 30,000 ng/µL.  Each reading finishes in 8 seconds or less. A slit cuvette mode handles OD600 culture measurements, and a built-in fluorometer quantifies samples below 2 ng/µL.

The instrument runs on a 10-inch touchscreen that tilts to suit each operator's working position. No external computer is needed, which saves bench space and simplifies validation. A built-in camera confirms that the liquid column has formed correctly before each reading. The software raises an alarm when purity ratios fall below user-set limits. Optional face recognition login restricts access to authorized users and protects stored data.

Results export by USB flash drive, print on the built-in printer, or transfer in real time over a local network by FTP.  Built-in protein, dye, and standard curve libraries store recurring methods so operators can recall them instead of re-entering settings. Integrated verification and calibration functions work with an optional performance verification solution. The pedestal design allows sample loading with either hand. No warm-up is required, so the instrument measures as soon as it powers on.

Full-Spectrum Microvolume Spectrophotometer - ToronMVS™ FS Applications

The ToronMVS™ FS serves labs that need full UV-Vis-NIR spectral data, very high concentration range, and fluorescence sensitivity in one benchtop instrument. Its preset methods cover nucleic acids, proteins, colorimetric assays, and cell culture density.

  • Nucleic Acid Quantification: dsDNA, ssDNA, RNA, oligonucleotide, and primer quantification with A260, A280, and A230 values and purity ratios
  • High-Concentration Samples: direct measurement of plasmid preps and genomic DNA up to 30,000 ng/µL without dilution
  • Labeled Probe Analysis: concentration and labeling checks on dye-labeled primers and probes using full-spectrum scans
  • Protein and Antibody Quantification: A280 measurement of proteins, antibodies, and peptides with custom extinction coefficients
  • Colorimetric Protein Assays: preset BCA, Bradford, Lowry, and 660 nm protein assay methods
  • Microbiology and Cell Culture: OD600 bacterial density measurement in slit cuvettes for growth curves and induction timing
  • Fluorometric Quantification: low-concentration dsDNA, RNA, protein, and oligo measurement, plus fluorescence kinetics
  • Nanoparticle and Dye Characterization: absorption peak identification across the 190 nm to 1100 nm range
Full-Spectrum Microvolume Spectrophotometer

Full-Spectrum Microvolume Spectrophotometer - ToronMVS™ FS Key Features

The ToronMVS™ FS combines full-spectrum microvolume absorbance, cuvette OD600, and fluorescence in a standalone instrument. Each feature targets wider measurement range, reliable readings, and secure data handling.

Full-Spectrum Microvolume Spectrophotometer

Precise Verification

Full-Spectrum Microvolume Spectrophotometer

Broad-Range Spectral Detection

Full-Spectrum Microvolume Spectrophotometer

Face Recognition

Full-Spectrum Microvolume Spectrophotometer

Sample Monitoring

Full-Spectrum Microvolume Spectrophotometer

Application Storage

Full-Spectrum Microvolume Spectrophotometer

Fluorometer Mode

Full-Spectrum Microvolume Spectrophotometer

Easy to Operate

Full-Spectrum Microvolume Spectrophotometer

Cuvette Function

  • 190 nm to 1100 nm Spectral Range: full UV-Vis-NIR coverage with automatic path switching or fixed-wavelength readings
  • Sample Volume of 0.5 µL to 2 µL: conserves precious samples, with recovery after measurement
  • dsDNA Range up to 30,000 ng/µL: six path lengths down to 0.02 mm measure concentrated samples without dilution
  • Results in 8 Seconds or Less: no warm-up, so measurements start immediately at power-on
  • Built-In Camera Monitoring: confirms liquid column formation before each reading to prevent unstable results
  • Purity Ratio Alarm: flags samples whose purity ratios fall below set limits
  • Fluorometer Mode: blue channel as standard, optional red channel, with detection down to 0.5 pg/µL dsDNA and real-time kinetics
  • OD600 Slit Cuvette Mode: measures bacterial density with low sample consumption across 0 to 4 Abs
  • 10-Inch Adjustable-Angle Touchscreen: tilts to the operator's preferred viewing angle and runs without a PC
  • Optional Face Recognition Login: controls user access at the source and protects data collection, storage, and retrieval
  • Flexible Data Export: USB flash drive, built-in printer, and real-time FTP transfer to networked computers
  • Built-In Method Libraries: stored protein, dye, and standard curve presets remove repeated setup
  • Verification and Calibration Functions: on-board routines with an optional performance verification solution
  • Two-Handed Sample Loading: pedestal layout allows comfortable loading with either hand

Theory and Method

UV-Vis spectrophotometry measures how much light a sample absorbs at each wavelength. The Beer-Lambert law links absorbance (A) to concentration (c) through A = εcl, where ε is the extinction coefficient and l is the path length. Nucleic acids absorb strongly at 260 nm, proteins at 280 nm, and many contaminants near 230 nm. Ratios such as A260/A280 and A260/A230 therefore reveal protein, phenol, or salt carryover. Extending the range to 1100 nm adds near-infrared data for dyes, nanoparticles, and turbidity checks.

Microvolume measurement replaces the cuvette with surface tension. The operator places a droplet on the lower pedestal, and the arm lowers a second optical fiber onto it. The droplet stretches into a liquid column between the two fiber ends. The ToronMVS™ FS then reads the column at path lengths as short as 0.02 mm, so even very concentrated samples stay within the detector's linear range. Software normalizes each reading to a 10 mm equivalent, giving an absorbance range up to 600 A.

A 2048-pixel linear CMOS array captures the full spectrum in one exposure, with 1 nm wavelength accuracy and resolution of 1.6 nm or better. For OD600, light passes through a slit cuvette, and the reading reflects light scattered by cells rather than true absorption. The fluorometer mode measures light emitted by target-specific dyes instead of absorbed light. Signal scales with target concentration, which pushes dsDNA detection down to 0.5 pg/µL.

Full-Spectrum Microvolume Spectrophotometer - ToronMVS™ FS Technical Specifications

Microvolume Absorbance Mode

ParameterSpecification
Wavelength Range190 nm to 1100 nm
Sample Volume0.5 µL to 2 µL
Optical Path Lengths0.02 mm, 0.03 mm, 0.05 mm, 0.1 mm, 0.2 mm, 1 mm
Light SourceNot specified in source
Detector2048-pixel linear silicon CMOS array
Wavelength Accuracy1 nm
Wavelength Resolution≤ 1.6 nm (FWHM at Hg 253.652 nm)
Absorbance Precision0.003 Abs (1 mm path)
Absorbance Accuracy±1% (7.332 Abs at 260 nm)
Absorbance Range0.04 A to 600 A (at 260 nm, 10 mm equivalent)
Nucleic Acid Detection Range2 ng/µL to 30,000 ng/µL (dsDNA)
A280 Protein Range (BSA)0.1 mg/mL to 900 mg/mL
Testing Time≤ 8 s
Pedestal MaterialAluminum alloy and quartz fiber

OD600 Cuvette Mode

ParameterSpecification
Cuvette TypeSlit cuvette
Absorbance Range0 Abs to 4.0 Abs
Absorbance Stability0 to 3 Abs: ≤ 0.5%; 3 to 4 Abs: ≤ 2%
Absorbance Repeatability0 to 3 Abs: ≤ 0.5%; 3 to 4 Abs: ≤ 2%
Absorbance Accuracy0 to 2 Abs: ≤ 0.005 Abs; 2 to 3 Abs: ≤ 1%; 3 to 4 Abs: ≤ 2%

Fluorometer Mode

ParameterSpecification
LinearityR² > 0.995
Repeatability< 1.5%
Stability< 1.5%
Sensitivity0.5 pg/µL (dsDNA)
Blue Channel (Standard)Excitation 460 nm ± 20 nm; emission 525 nm to 570 nm
Red Channel (Optional)Excitation 625 nm ± 20 nm; emission 670 nm to 725 nm

General Specifications

ParameterSpecification
Display10-inch adjustable-angle touchscreen
SoftwareAndroid-based
Sample MonitoringBuilt-in camera for liquid column verification
Data ExportUSB flash drive, built-in printer, FTP over local network
User AccessOptional face recognition module
Input VoltageDC 24 V, 2 A
Power25 W
Dimensions (W × D × H)260 × 333 × 346 mm
Weight5.8 kg

Optional Accessories

ItemDescription
Performance Verification SolutionReference solution for on-board instrument verification and calibration
Face Recognition ModuleBiometric login for controlled user access
Red Fluorescence ChannelAdditional channel for Cy5-labeled probes and RNA quantification dyes
OD600 CuvetteSlit cuvette for bacterial culture density measurement