Atomic Fluorescence Spectrometer – ToronAFS™-310
Atomic Fluorescence Spectrometer – ToronAFS™-310
Atomic Fluorescence Spectrometer – ToronAFS™ 310 is a high-precision analytical instrument designed for ultra-trace elemental analysis using atomic fluorescence spectrometry. The system excites target elements with element-specific light and measures the emitted fluorescence to determine elemental concentrations with exceptional sensitivity and accuracy.
This Atomic Fluorescence Spectrometer is optimized for routine and advanced laboratories requiring reliable detection of toxic and trace elements such as mercury, arsenic, selenium, antimony, bismuth, cadmium, lead, and zinc. With a compact footprint, dual-channel design, and intelligent automation, the ToronAFS-310 delivers laboratory-grade results while remaining easy to operate, even for users new to atomic fluorescence analysis.
Atomic Fluorescence Spectrometer – ToronAFS™-310 Applications
The Atomic Fluorescence Spectrometer – ToronAFS™ 310 is suitable for:
- Environmental Monitoring – Trace detection of mercury and heavy metals in water, soil, and air-related samples
- Food Safety & Agriculture – Analysis of toxic elements in food, feed, fertilizers, and agricultural products
- Clinical & Public Health Laboratories – Elemental screening for exposure and contamination studies
- Geological & Metallurgical Analysis – Determination of trace elements in ores, minerals, and metals
- Petrochemical & Industrial Testing – Monitoring elemental impurities in industrial materials
- Research & Education – Teaching, method development, and analytical research applications
Atomic Fluorescence Spectrometer – ToronAFS™-310 Key Features
- Dual-Channel Atomic Fluorescence Design
- Enables simultaneous analysis of two elements, improving throughput and detection sensitivity
- High-Sensitivity Element Detection
- Optimized for ultra-trace analysis of 11 key elements including Hg, As, Se, Sb, Bi, Cd, Pb, Sn, and Zn
- Real-Time Flame Observation System
- Integrated flame monitoring allows users to observe flame conditions directly, reducing interference and improving measurement stability
- Intelligent Gas Flow Control System
- Fully automated gas flow regulation with abnormal condition diagnostics and automatic gas cutoff for enhanced safety
- High-Performance Hollow Cathode Lamps
- Intelligent lamp recognition, lifetime tracking, and optimized excitation ensure consistent analytical performance
- Single-Standard Calibration Capability
- Simplifies standard curve preparation while supporting automatic dilution and pipeline cleaning
- Efficient Gas–Liquid Separation
- Minimizes water vapor interference, improving accuracy and repeatability
- User-Friendly Operating Software
- Windows-based interface with automated qualitative and quantitative analysis, data calculation, and report generation
Atomic Fluorescence Spectrometer – ToronAFS™-310 Technical Specifications
| Specification | ToronAFS™ 310 |
|---|---|
| Instrument Type | Atomic Fluorescence Spectrometer |
| Detection Channels | Dual-channel |
| Elements Detected | Hg, As, Sb, Bi, Se, Te, Cd, Ge, Pb, Sn, Zn |
| Detection Limit (DL) | Hg, As, Sb, Bi, Se, Te, Pb, Sn ≤ 0.01 µg/L; Cd ≤ 0.001 µg/L; Zn ≤ 0.05 µg/L; Ge ≤ 0.05 µg/L |
| Precision (RSD) | ≤ 1% |
| Linear Range | Greater than three orders of magnitude |
| Injection System | Dual peristaltic pump intermittent flow injection |
| Flame Observation | Real-time integrated monitoring |
| Gas Control | Fully automatic gas flow control with safety interlock |
| Light Source | Intelligent high-performance hollow cathode lamps |
| Software | Windows-based, bilingual interface, automated analysis and reporting |
| Sample Preparation | Supports single-standard calibration and automatic dilution |
| Voltage | 220V (110V is also available) |
| Detection limit (Cu) | <0.008ug/ml |
| Wavelength Range | 190nm ~ 900nm |
| Characteristic concentration | < 0.025µg/ml/1% |
| Resolution ratio | Better than 0.3nm |
| Packaging Dimension | 880 X 760 X 650 mm |