High-Capacity & High Speed Centrifuge PRO 2515 can accommodate 14 different rotors and versatile adapters, allowing for a wide range of centrifugation applications in medium-throughput molecular biology. It is compatible with various test tubes from 0.2ml to 400ml, including microtubes, PCR strip tubes, microplates, 15/50ml conical tubes, and blood collection tubes.

Application Fields

  • Clinical chemistry, hematology, serology, and cell cultivation.
  • Hospitals, research institutes, colleges and universities, and testing centers.

  • Compatible with 14 different rotor models.
  • Swing bucket rotor for MTP microplates, PCR plates, cell cultivation plates, and deep well plates.
  • Fixed angle rotor for applications requiring high centrifugal forces.
  • Optimized airflow to minimize sample warming during operation.
  • Parameter adjustment via rotary knob and touch screen.
  • Instantaneous centrifugation with one-touch start.
  • Soft brake to prevent resuspension of sensitive samples.
  • Automatic rotor imbalance detection for safer centrifugation.
  • Automatic rotor recognition with speed limit control.
  • Rotor service time record and replacement reminder for safety.
  • Storage for 50 routine programs with quick preview of program parameters.
  • Eight program shortcuts for quick access to frequently used programs.
  • Emergency lid opening function for unexpected incidents such as power failures.
  • Optional gas-tight rotor cap for centrifuging hazardous samples.

SpecificationPRO 2515 (Non-Refrigerated)PRO 2515R (Refrigerated)
Voltage220VAC (110V available)220VAC (110V available)
Frequency50/60Hz50/60Hz
Power1000W1.5KW
Max. Current4.6A6.8A
Max. Capacity4 × 400 ml / 2 × 5 MTP4 × 400 ml / 2 × 5 MTP
Max. Speed15000 rpm, 50 rpm increment15000 rpm, 50 rpm increment
Max. RCF23897 × g, 10 × g increment23897 × g, 10 × g increment
Time Setting30 s to 99 h 59 min30 s to 99 h 59 min
Dimensions (L × W × H)465 × 580 × 380 mm625 × 580 × 380 mm
Weight55 kg80 kg
Noise Level≤ 62 dB≤ 62 dB
Temperature Range--20°C to 40°C
Item No.26.748.000126.749.0001
Swing-bucket rotors  
 Number of bucketsModelMax. RCFMax. SpeedMax. capacityItem No.
4H-04-2503234xg4200 rpm0.2-250 ml06.749.2001
4H-08-504584xg5000 rpm0.2-100 ml06.749.2002
2H-02-DWP2250xg3700 rpmDeep well plate06.749.2003
4H-04-1004500xg5000 rpm0.2-100 ml06.749.2004
6H-06-216435xg14000 rpm1.5/2.0 ml06.749.2005
4HA-04-4003848xg4500 rpm4x400 ml06.749.2006
Fixed-angle rotors 
 ModelMax. RCFMax. SpeedMax. capacity (Place*Volume)Item No.
SA-20-520913xg13100 rpm20x5ml06.749.1001
SA-06-8515016xg11000 rpm6x85 ml06.749.1002
S-06-5015016xg11000 rpm6x50 ml06.749.1003
SA-48-220376xg13500 rpm48x1.5/2.0 ml06.749.1004
SA-30-223897xg15000 rpm30x1.5/2.0 ml06.749.1005
S-40-154193xg5000 rpm40x15 ml06.749.1007
S-64-PCR15777xg14000 rpm64x0.2ml PCR06.749.1009
SA-08-506802xg6500 rpm8x50 ml06.749.1010
4 Swing-bucket rotor | H-04-250
Max. RCF3234xg
Max. speed4200 rpm
Max. capacity0.2ml-250ml
Acceleration Time30s
Angle0°
Temperature+4°C
Item No.06.749.2001
      
Centrifuge tube
Volume (ml)1.52101550250
Diameter x length (mm)11x4611x4617x10517x12229.5x10262x135
      
Adapter
Volume (ml)104x2104x232x10ml-15ml32x10ml-15ml16x504x250
Item No.07.749.020107.749.020107.749.020207.749.020207.749.020307.749.0204
4 Swing-bucket rotor | H-04-100
Max. RCF4500xg
Max. speed5000 rpm
Max. capacity0.2ml-100ml
Acceleration Time30s
Angle0°
Temperature+4°C
Item No.06.749.2004
      
Centrifuge tube
Volume (ml)1.52101550100
Diameter x length (mm)11x4611x4617x10517x12229.5x12042x113
      
Adapter
Volume (ml)96x296x216x10ml-15ml16x10ml-15ml4x504x100
Item No.07.749.060107.749.060107.749.060207.749.060207.749.060307.749.0604
4 Swing-bucket rotor | HA-04-4000
Max. RCF3848xg
Max. speed4500 rpm
Max. capacity4x400 ml
Acceleration Time30s
Angle0°
Temperature+4°C
Item No.06.749.2006
      
Centrifuge tube
Volume (ml)1.525101525
Diameter x length (mm)11x4611x4613x5317x10517x12220.5x110
      
Adapter
Volume (ml)152x2152x264x536x10ml-15ml36x10ml-15ml24x25
Item No.07.749.130107.749.130107.749.130207.749.130307.749.130307.749.1304
      
Centrifuge tube
Volume (ml)305050100200250
Diameter x length (mm)25.5x10229.5x12029.5x11542x11362x12562x135
      
Adapter
Volume (ml)20x3016x5016x504x1004x2004x250
Item No.07.749.130507.749.130607.749.130707.749.130807.749.130907.749.1310
 
Centrifuge tube
Volume (ml)400
Diameter x length (mm)80x125

Request Quote