Full-Spectrum Microvolume Spectrophotometer

Danh mục Sản phẩm

Full-Spectrum Microvolume Spectrophotometer - ToronMVS™ FS

ToronMVS™ FS Full-Spectrum Microvolume Spectrophotometer with Cuvette Capability

The ToronMVS™ FS full-spectrum microvolume spectrophotometer measures absorbance across 190 nm to 1100 nm using as little as 0.5 µL of sample. Genomics cores, protein labs, and biotech QC teams use it to quantify nucleic acids, proteins, and labeled molecules without dilution. Six path lengths, as short as 0.02 mm, extend the dsDNA range up to 30,000 ng/µL.  Each reading finishes in 8 seconds or less. A slit cuvette mode handles OD600 culture measurements, and a built-in fluorometer quantifies samples below 2 ng/µL.

The instrument runs on a 10-inch touchscreen that tilts to suit each operator's working position. No external computer is needed, which saves bench space and simplifies validation. A built-in camera confirms that the liquid column has formed correctly before each reading. The software raises an alarm when purity ratios fall below user-set limits. Optional face recognition login restricts access to authorized users and protects stored data.

Results export by USB flash drive, print on the built-in printer, or transfer in real time over a local network by FTP.  Built-in protein, dye, and standard curve libraries store recurring methods so operators can recall them instead of re-entering settings. Integrated verification and calibration functions work with an optional performance verification solution. The pedestal design allows sample loading with either hand. No warm-up is required, so the instrument measures as soon as it powers on.

Full-Spectrum Microvolume Spectrophotometer - ToronMVS™ FS Applications

The ToronMVS™ FS serves labs that need full UV-Vis-NIR spectral data, very high concentration range, and fluorescence sensitivity in one benchtop instrument. Its preset methods cover nucleic acids, proteins, colorimetric assays, and cell culture density.

  • Định lượng axit nucleic: dsDNA, ssDNA, RNA, oligonucleotide, and primer quantification with A260, A280, and A230 values and purity ratios
  • High-Concentration Samples: direct measurement of plasmid preps and genomic DNA up to 30,000 ng/µL without dilution
  • Labeled Probe Analysis: concentration and labeling checks on dye-labeled primers and probes using full-spectrum scans
  • Protein and Antibody Quantification: A280 measurement of proteins, antibodies, and peptides with custom extinction coefficients
  • Colorimetric Protein Assays: preset BCA, Bradford, Lowry, and 660 nm protein assay methods
  • Microbiology and Cell Culture: OD600 bacterial density measurement in slit cuvettes for growth curves and induction timing
  • Định lượng huỳnh quang: low-concentration dsDNA, RNA, protein, and oligo measurement, plus fluorescence kinetics
  • Nanoparticle and Dye Characterization: absorption peak identification across the 190 nm to 1100 nm range
Full-Spectrum Microvolume Spectrophotometer

Full-Spectrum Microvolume Spectrophotometer - ToronMVS™ FS Key Features

The ToronMVS™ FS combines full-spectrum microvolume absorbance, cuvette OD600, and fluorescence in a standalone instrument. Each feature targets wider measurement range, reliable readings, and secure data handling.

Full-Spectrum Microvolume Spectrophotometer

Precise Verification

Full-Spectrum Microvolume Spectrophotometer

Broad-Range Spectral Detection

Full-Spectrum Microvolume Spectrophotometer

Nhận diện khuôn mặt

Full-Spectrum Microvolume Spectrophotometer

Sample Monitoring

Full-Spectrum Microvolume Spectrophotometer

Lưu trữ ứng dụng

Full-Spectrum Microvolume Spectrophotometer

Fluorometer Mode

Full-Spectrum Microvolume Spectrophotometer

Dễ dàng hoạt động

Full-Spectrum Microvolume Spectrophotometer

Cuvette Function

  • 190 nm to 1100 nm Spectral Range: full UV-Vis-NIR coverage with automatic path switching or fixed-wavelength readings
  • Sample Volume of 0.5 µL to 2 µL: conserves precious samples, with recovery after measurement
  • dsDNA Range up to 30,000 ng/µL: six path lengths down to 0.02 mm measure concentrated samples without dilution
  • Results in 8 Seconds or Less: no warm-up, so measurements start immediately at power-on
  • Built-In Camera Monitoring: confirms liquid column formation before each reading to prevent unstable results
  • Purity Ratio Alarm: flags samples whose purity ratios fall below set limits
  • Fluorometer Mode: blue channel as standard, optional red channel, with detection down to 0.5 pg/µL dsDNA and real-time kinetics
  • OD600 Slit Cuvette Mode: measures bacterial density with low sample consumption across 0 to 4 Abs
  • 10-Inch Adjustable-Angle Touchscreen: tilts to the operator's preferred viewing angle and runs without a PC
  • Optional Face Recognition Login: controls user access at the source and protects data collection, storage, and retrieval
  • Xuất dữ liệu linh hoạt: USB flash drive, built-in printer, and real-time FTP transfer to networked computers
  • Built-In Method Libraries: stored protein, dye, and standard curve presets remove repeated setup
  • Verification and Calibration Functions: on-board routines with an optional performance verification solution
  • Two-Handed Sample Loading: pedestal layout allows comfortable loading with either hand

Lý thuyết và Phương pháp

UV-Vis spectrophotometry measures how much light a sample absorbs at each wavelength. The Beer-Lambert law links absorbance (A) to concentration (c) through A = εcl, where ε is the extinction coefficient and l is the path length. Nucleic acids absorb strongly at 260 nm, proteins at 280 nm, and many contaminants near 230 nm. Ratios such as A260/A280 and A260/A230 therefore reveal protein, phenol, or salt carryover. Extending the range to 1100 nm adds near-infrared data for dyes, nanoparticles, and turbidity checks.

Microvolume measurement replaces the cuvette with surface tension. The operator places a droplet on the lower pedestal, and the arm lowers a second optical fiber onto it. The droplet stretches into a liquid column between the two fiber ends. The ToronMVS™ FS then reads the column at path lengths as short as 0.02 mm, so even very concentrated samples stay within the detector's linear range. Software normalizes each reading to a 10 mm equivalent, giving an absorbance range up to 600 A.

A 2048-pixel linear CMOS array captures the full spectrum in one exposure, with 1 nm wavelength accuracy and resolution of 1.6 nm or better. For OD600, light passes through a slit cuvette, and the reading reflects light scattered by cells rather than true absorption. The fluorometer mode measures light emitted by target-specific dyes instead of absorbed light. Signal scales with target concentration, which pushes dsDNA detection down to 0.5 pg/µL.

Full-Spectrum Microvolume Spectrophotometer - ToronMVS™ FS Technical Specifications

Microvolume Absorbance Mode

Tham sốĐặc điểm kỹ thuật
Dải bước sóng190 nm đến 1100 nm
Khối lượng mẫu0.5 µL đến 2 µL
Optical Path Lengths0.02 mm, 0.03 mm, 0.05 mm, 0.1 mm, 0.2 mm, 1 mm
Nguồn sángKhông được nêu rõ trong nguồn.
Máy dò2048-pixel linear silicon CMOS array
Độ chính xác bước sóng1 nm
Độ phân giải bước sóng≤ 1.6 nm (FWHM at Hg 253.652 nm)
Độ chính xác hấp thụ0.003 Abs (1 mm path)
Độ chính xác của phép đo độ hấp thụ±1% (7.332 Abs at 260 nm)
Phạm vi hấp thụ0.04 A to 600 A (at 260 nm, 10 mm equivalent)
Phạm vi phát hiện axit nucleic2 ng/µL to 30,000 ng/µL (dsDNA)
A280 Protein Range (BSA)0.1 mg/mL đến 900 mg/mL
Thời gian thử nghiệm≤ 8 giây
Vật liệu bệ đỡAluminum alloy and quartz fiber

OD600 Cuvette Mode

Tham sốĐặc điểm kỹ thuật
Loại cuvetSlit cuvette
Phạm vi hấp thụ0 Abs to 4.0 Abs
Độ ổn định hấp thụ0 to 3 Abs: ≤ 0.5%; 3 to 4 Abs: ≤ 2%
Độ lặp lại của độ hấp thụ0 to 3 Abs: ≤ 0.5%; 3 to 4 Abs: ≤ 2%
Độ chính xác của phép đo độ hấp thụ0 to 2 Abs: ≤ 0.005 Abs; 2 to 3 Abs: ≤ 1%; 3 to 4 Abs: ≤ 2%

Fluorometer Mode

Tham sốĐặc điểm kỹ thuật
Tuyến tínhR² > 0.995
Độ lặp lại<1.5%
Tính ổn định<1.5%
Độ nhạy0.5 pg/µL (dsDNA)
Blue Channel (Standard)Excitation 460 nm ± 20 nm; emission 525 nm to 570 nm
Red Channel (Optional)Excitation 625 nm ± 20 nm; emission 670 nm to 725 nm

Thông số kỹ thuật chung

Tham sốĐặc điểm kỹ thuật
Giao diện10-inch adjustable-angle touchscreen
Phần mềmDựa trên Android
Sample MonitoringBuilt-in camera for liquid column verification
Xuất dữ liệuUSB flash drive, built-in printer, FTP over local network
Người dùng truy cậpOptional face recognition module
Điện áp đầu vàoDC 24 V, 2 A
Power25 W
Kích thước (W × D × H)260 × 333 × 346 mm
Trọng lượng máy5.8 kg

Phụ kiện tùy chọn

Mục Mô tả Chi tiết
Performance Verification SolutionReference solution for on-board instrument verification and calibration
Mô-đun nhận dạng khuôn mặtBiometric login for controlled user access
Red Fluorescence ChannelAdditional channel for Cy5-labeled probes and RNA quantification dyes
OD600 CuvetteSlit cuvette for bacterial culture density measurement

NHẬN BÁO GIÁ