96-Channel Liquid Handling Workstation

Danh mục Sản phẩm

96-Channel Liquid Handling Workstation - ToronLH™ 96 Series

ToronLH™ 96 Series Automated 96-Channel Pipetting Workstation

The ToronLH™ 96 Series 96-channel liquid handling workstation fills, transfers, mixes, and dilutes an entire 96-well plate in one pipetting stroke. Molecular biology, immunoassay, and cell culture labs use it in place of repetitive manual multichannel pipetting. Swappable 96-channel heads cover 1 µL to 1000 µL, and the system also pipettes 8 channels at a time. A moving plate table carries plates under the fixed head, so each transfer stays aligned. Operators build and run protocols from an Android tablet over a cable or Bluetooth.

Four models match different throughput and volume needs. The ToronLH™ 96A2 and 96A4 hold 2 or 4 plate positions and accept the 20 µL and 200 µL heads. The 96B2 and 96B4 add support for a 1000 µL head for larger transfers. The four-position models also unlock an advanced software mode for longer, multi-plate protocols. Custom 3-position or 6-position layouts are available on request.

The two-position models measure only 475 mm wide, small enough for a biosafety cabinet, clean bench, or fume hood. Bluetooth control lets operators run protocols with the cabinet sash closed. Pipetting heads swap by hand in a few steps with no tools or service visit. Each head stores its calibration data on a QR code, which the tablet scans when the head goes in. The instrument then identifies the head type automatically.

96-Channel Liquid Handling Workstation - ToronLH™ 96 Series Applications

The ToronLH™ 96 Series handles any workflow that moves liquid between SBS-format plates, reservoirs, and deep-well blocks. Its full-plate transfers cut hands-on time for both routine and complex multi-step protocols.

  • Thiết lập PCR và qPCR: dispensing master mix and transferring templates into 96-well and 384-well PCR plates
  • ELISA and Immunoassays: reagent addition, sample transfer, and serial dilution of standards across plate rows
  • Cell Culture and Cell-Based Assays: medium exchange, compound addition, and siRNA treatment inside a biosafety cabinet
  • NGS Sample Preparation: reagent dispensing and sample transfers for sequencing library preparation and purification
  • Drug and Compound Screening: plate replication and compound transfer between source and assay plates
  • Xét nghiệm Enzym: substrate and enzyme addition for routine enzyme activity experiments
  • kết tinh protein: precise low-volume dispensing of protein and crystallization reagents
  • Nucleic Acid Extraction Prep: filling deep-well plates with lysis, wash, and elution reagents for magnetic bead extractors
  • 384-Well Plate Work: quadrant transfers between 96-well and 384-well plates with the 384-well adapter
96-Channel Liquid Handling Workstation

96-Channel Liquid Handling Workstation - ToronLH™ 96 Series Key Features

The ToronLH™ 96 Series combines full-plate pipetting, swappable heads, and wireless tablet control in a compact benchtop instrument. Each feature targets faster plate processing, consistent volumes, and simple setup.

  • 96-Channel or 8-Channel Pipetting: process a full plate in one stroke or work column by column
  • Three Swappable Head Sizes: 1 µL to 20 µL, 5 µL to 200 µL, and 100 µL to 1000 µL (1000 µL on 96B models)
  • Tool-Free Head Changes: release the handles and slide the head out without assistance
  • QR Code Calibration Data: each head stores its calibration on a QR code that the tablet reads at installation
  • Automatic Head Recognition: the instrument identifies the installed head type automatically
  • 2 or 4 Plate Positions: automatic plate table movement, with custom 3- or 6-position layouts on request
  • Biosafety Cabinet Size: 2-position models fit inside clean benches, safety cabinets, and fume hoods
  • Wired or Bluetooth Control: run protocols through a cable or wirelessly with the cabinet closed
  • Máy tính bảng Android 8 inch: graphical protocol editing, saved programs, and built-in user management
  • Basic and Advanced Software Modes: advanced mode on 4-position models supports complex multi-plate protocols
  • Full Pipetting Function Set: aspirate, dispense, blowout, continuous blowout, column-selective aspiration, stepper pipetting, mixing, dilution, and reverse pipetting
  • Adjustable Liquid Speeds: set aspirate and dispense speeds to suit viscous, volatile, or foaming liquids
  • SBS Plate Compatibility: 24, 96, and 384-well plates, deep-well and shallow, plus reservoirs
  • Nút Dừng khẩn cấp: halts motion at once for operator safety
96-Channel Liquid Handling Workstation

Lý thuyết và Phương pháp

The ToronLH™ 96 Series uses air displacement pipetting, the same principle as a handheld air-cushion pipette. Each of the 96 channels has a piston inside a cylinder, with a tip pressed onto the end. When the piston rises, it lowers the air pressure in the tip and draws liquid in. When the piston falls, the air cushion pushes the liquid back out. Because the air gap separates the piston from the sample, liquid never touches the mechanism.

All 96 pistons move together on a single drive, so every well receives the same volume at the same moment. Precision depends on how finely the drive controls piston travel, which allows minimum steps of 0.1 µL on the 20 µL head. Liquids with different viscosity or surface tension behave differently in an air cushion. Adjustable aspirate and dispense speeds compensate for these differences. Reverse pipetting draws an extra volume and leaves it behind, which improves accuracy for viscous or foaming liquids.

The software combines these basic moves into higher-level functions. Mixing aspirates and dispenses repeatedly in the same well to blend sample and reagent evenly. Serial dilution moves a fixed volume across successive rows or plates to build a dilution series. Stepper pipetting draws once and dispenses several equal aliquots. Program linkage chains steps across plate positions into complete multi-step protocols.

96-Channel Liquid Handling Workstation - ToronLH™ 96 Series Technical Specifications

Mô hình máy trạm

Tham sốToronLH™ 96A2ToronLH™ 96A4ToronLH™ 96B2ToronLH™ 96B4
Plate Positions2424
Đầu tương thích20 µL, 200 µL20 µL, 200 µL20 µL, 200 µL, 1000 µL20 µL, 200 µL, 1000 µL
Chế độ phần mềmCơ bảnBasic and advancedCơ bảnBasic and advanced
Các kênh8 / 968 / 968 / 968 / 96
Power100 W100 W100 W100 W
Khối lượng tịnh26 kg30 kg29 kg33 kg
Kích thước (W × D × H)475 × 343 × 535 mm690 × 343 × 535 mm475 × 350 × 673 mm690 × 350 × 673 mm

Thông số kỹ thuật được chia sẻ

Tham sốĐặc điểm kỹ thuật
Nguyên lý hút pipetDịch chuyển không khí
Tấm tương thíchSBS standard 24, 96, and 384-well plates, deep-well and shallow
Tuỳ chỉnh Giao diện3 or 6 plate positions on request
Người điều khiểnStandard 8-inch Android tablet; software adapts to common tablet sizes
Giao tiếpCó thể xe buýt
Kiểm soát không dâyMô-đun Bluetooth tích hợp
Sự An ToànNút dừng khẩn cấp
điện áp100 V đến 240 V AC, 50/60 Hz

Thông số kỹ thuật đầu pipet

Tham số20 µL Head200 µL Head1000 µL Head
Các kênh969696
Phạm vi hút pipet1 µL đến 20 µL5 µL đến 200 µL100 µL đến 1000 µL
Tăng Tối Thiểu0.1µL0.2µL1µL
tính chính xác≤ ±12% at 1 µL; ≤ ±12% at 2 µL; ≤ ±8% at 10 µL; ≤ ±1% at 20 µL≤ ±5% at 5 µL; ≤ ±2% at 20 µL; ≤ ±1% at 100 µL; ≤ ±1% at 200 µL≤ ±2% at 100 µL; ≤ ±1% at 500 µL; ≤ ±1% at 1000 µL
Precision (CV)≤ 10% at 1 µL; ≤ 5% at 2 µL; ≤ 1% at 10 µL; ≤ 0.8% at 20 µL≤ 3.5% at 5 µL; ≤ 1.5% at 20 µL; ≤ 0.8% at 100 µL; ≤ 0.4% at 200 µL≤ 1% at 100 µL; ≤ 0.4% at 500 µL; ≤ 0.4% at 1000 µL
Các mô hình tương thíchTất cả các mô hìnhTất cả các mô hình96B2, 96B4
Dữ liệu hiệu chuẩnStored on QR code, scanned by tabletStored on QR code, scanned by tabletStored on QR code, scanned by tablet
Head RecognitionTự độngTự độngTự động

Phụ kiện và Vật tư tiêu hao

Mục Mô tả Chi tiết
20 µL 96-Channel HeadInterchangeable head for 1 µL to 20 µL transfers
200 µL 96-Channel HeadInterchangeable head for 5 µL to 200 µL transfers
1000 µL 96-Channel HeadInterchangeable head for 100 µL to 1000 µL transfers (96B models)
384-Well AdapterAdapter for pipetting into 384-well plates
Mẹo Pipette20 µL, 200 µL, and 1000 µL racked tips in standard, low-retention, sterile, and filtered versions
96 Deep-Well Plates1.6 mL, 2.0 mL, and 2.2 mL formats
96-Well Elution Plate0.6 mL plate for purified nucleic acid collection
V-Bottom Reservoir96-well V-bottom reagent reservoir

NHẬN BÁO GIÁ