ENVIRONMENTAL TEST CHAMBER - Noxious Gas Test Chamber

Noxious Gas Test Chamber

SO2 Noxious Gas Test Chamber can be used to test the product's resistance to gas corrosion by simulating gas corrosion environments

SO2 Noxious Gas Test Chamber can be used to test the product's resistance to gas corrosion by simulating gas corrosion environments.

SO2 Noxious Gas Test Chambers reproduce damages by temperature, relative humidity and noxious gas corrosion to material,

components and constructions. This test chamber can be used for single gas tests. LIB SO2 Noxious Gas Test Chambers can be used to test SO2, H2S, HCL, NO2, CL2.

SO2 gas tests comply with standard of IEC 60068-2-42.

  • Heated Viewing Window: Heated viewing window allows viewing fog generated and proper viewing of the test sample.
  • Energy Efficient  Noxious Gas Chamber uses less energy to provide the same level of performance, comfort and convenience, thus making it energy conserving chamber.
  • Low Maintenance - SO2 Gas Test Chamber benefit in retaining proper functionality over long period of time.
  • Floor Type
  • Automatic measure and control gas
  • Temperature control and display unit
  • Humidity control and display unit
  • Test SO2 H2S CO2 HCL single gas and mixed
  • Programmable color LCD touch screen controller
  • USB and Ethernet
  • Electromagnetic lock to prevent door from opening under working
  • Air cooled refrigeration system
  • Casters, shelf and cable port are standard
  • Safety protection system
  • Model
    TT-SO-100
    TT-SO-225
    TT-SO-500
    TT-SO-800
    TT-SO-1000
    Internal Dimensions (mm)
    450*450*500
    500*600*750
    800*700*900
    800*1000*1000
    1000*1000*1000
    Overall Dimensions (mm)
    1050*880*1440
    1050*1020*2000
    1320*1320*2170
    1470*1520*2315
    1670*1520*2315
    Interior Volume (L)
    100
    225
    500
    800
    1000
    Temperature Range
    15°C ~ 80°C
    TemperatureFluctuation
    ±0.5°C
    TemperatureDeviation
    ±2.0°C
    Humidity Range
    30% ~ 98% RH
    Humidity Deviation
    ±1 RH
    SO2 Concentration
    25±5 ppm
    Air Change Rate
    3~5 /h
    Cooling
    Cooling system
    Mechanical compression refrigeration system
    Refrigerating unit
    French TECUMSEH compressor
    Refrigerant
    R404A
    Heating Element
    Nichrome heater
    Humidity
    Humidifier
    External isolation, stainless steel surface evaporation humidifier
    Water Supply System
    Water purification system
    Automatic water supply
    Dehumidification
    Evaporator
    Controller
    Programmable color LCD touch screen controller
    Ethernet connection, PC Link
    Sensor
    Temperature Sensor
    PT100Ω / MV A-class
    Humidity Sensor
    Dry and wet bulb sensor
    Gas Sensor
    SO2 gas sensor
    Build-in Water Tank(mm)
    270*300*400
    270*300*450
    View Window Size (mm)
    250*280
    300*330
    330*370
    Air Circulation
    Centrifugal wind fan
    Door Lock
    Electromagnetic lock
    Gas Exhaust Device
    SO2 Exhaust Unit
    Safety Device
    Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection;Water Shortage Protection; Earth leakage Protection
    Interior material
    SUS304 stainless steel +Glass fiber reinforced plastics
    Exterior material
    Steel Plate with protective coating
    Power Supply
    380V 50Hz
    Maximum Noise
    65 dBA
    Standard
    IEC60068-2-42; IEC60068-2-60
    Environmental Conditional
    5°C ~ +35°C ≤85% RH
    Quote Form

    HOW CAN WE HELP YOU ?

    Contact our sales team for a quotation.

    Please Contact us for pricing, check availability, or ask for additional information about our Noxious Gas Test Chamber
    Scroll to Top